If you’re running a script or application, please register or sign in with your developer credentials here. Additionally make sure your User-Agent is not empty and is something unique and descriptive and try again. if you’re supplying an alternate User-Agent string, try changing back to default as that can sometimes result in a block.
You can read Reddit’s Terms of Service here.
if you think that we’ve incorrectly blocked you or you would like to discuss easier ways to get the data you want, please file a ticket here.
when contacting us, please include your ip address which is: 178.132.111.61 and reddit account
Производительность raid контроллера
Обнаружил, что падает скорость записи на массив, raid 10. Скорость записи-чтения проверяю локально, просто rsync-ом. На 4х дисках в 10 raid, sas rpm15k, скорость записи достигает 30-40 Мб/сек.
Это же не дело?
Отдельно диски тестировал до сборки массива, все пишут примерно по 175-180 мб/сек
Контроллер ServeRAID M5110, внутри 800 MHz dual-core IBM PowerPC® processor with LSI SAS2208 6 Gbps RAID on Chip (ROC) controller , батарейки нет, памяти вроде 512мб.
Полез смотреть опции чтения и кэширования, а там:
Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 557.75 GB Sector Size : 512 Is VD emulated : No Mirror Data : 557.75 GB State : Optimal Strip Size : 64 KB Number Of Drives per span:2 Span Depth : 2 Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disabled Encryption Type : None Is VD Cached: No
На другом сервере, с такими же дисками, такой проблемы нет, и там скорость чтения\записи приемлемая, однако, там контроллер уже такой:
Intel(R) RAID Controller SRCSASLS4I
и там стоит LSI LSISAS2008 ROC device , т.е. контроллер менее производительный. и там имеется следующая конфигурация массива:
Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 271.945 GB Sector Size : 512 Mirror Data : 271.945 GB State : Optimal Strip Size : 64 KB Number Of Drives per span:2 Span Depth : 2 Default Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteThrough, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Is VD Cached: No
Вопрос состоит в том, может ли ReadAheadNone и Disk Cache Policy : Disabled давать такую просадку в скорости массива?
Конфигурация ADAPTEC 78165 на использование Write-Cache
Добрый день, уважаемые специалисты!
Домашняя система, данные некритичны, UPS есть, AFM-700 нет.
В данный момент подключил к 78165 два HDD в режиме Single Drive, цель рост производительности по сравнению с 3 Gbps портам контроллера Intel X79 за счет использования 1024 МБ кэша устройства.
Конфигурация сейчас такая, смущает вот этот вот момент «Write-cache status : Off» :
C:\Windows\system32>arcconf getconfig 1 Controllers found: 1 ---------------------------------------------------------------------- Controller information ---------------------------------------------------------------------- Controller Status : Optimal Controller Mode : Simple Volume Controller Cache Preservation : Enabled Channel description : SAS/SATA Controller Model : Adaptec ASR78165 Controller Serial Number : 3A32133C2FA Controller World Wide Name : 50000D1107221500 Controller Alarm : Enabled Physical Slot : 3 Temperature : 44 C/ 111 F (Normal) Installed memory : 1024 MB Global task priority : High Performance Mode : Default/Dynamic Host bus type : PCIe Host bus speed : 8000 MHz Host bus link width : 8 bit(s)/link(s) PCI Device ID : 652 Stayawake period : Disabled Spinup limit internal drives : 0 Spinup limit external drives : 0 Defunct disk drive count : 0 Logical devices/Failed/Degraded : 2/0/0 NCQ status : Enabled Statistics data collection mode : Enabled Global Physical Device Write Cache Policy: Enabled Monitor Log Severity Level : Informational -------------------------------------------------------- RAID Properties -------------------------------------------------------- Copyback : Disabled Automatic Failover : Enabled Background consistency check : Enabled Background consistency check period : 30 -------------------------------------------------------- Controller BIOS Setting Information -------------------------------------------------------- Runtime BIOS : Disabled Array BBS Support : Enabled Physical Drives Displayed during POST : Enabled Backplane Mode : IBPI BIOS Halt on Missing Drive Count : 255 -------------------------------------------------------- Controller Version Information -------------------------------------------------------- BIOS : 7.5-0 (32106) Firmware : 7.5-0 (32106) Driver : 7.5-0 (41063) Boot Flash : 7.5-0 (32106) CPLD (Load version/ Flash version) : 8/ 10 SEEPROM (Load version/ Flash version) : 1/ 1 -------------------------------------------------------- Controller Cache Backup Unit Information -------------------------------------------------------- Overall Backup Unit Status : Not Present ---------------------------------------------------------------------- Logical device information ---------------------------------------------------------------------- Logical Device number 0 Logical Device name : VOLUME 1 Block Size of member drives : 512 Bytes RAID level : Simple_volume Unique Identifier : A1484B2C Status of Logical Device : Optimal Size : 3814390 MB Parity space : Not Applicable Read-cache setting : Enabled Read-cache status : On Write-cache setting : Enabled Write-cache status : Off Partitioned : Yes Protected by Hot-Spare : Not Applicable Bootable : Yes Failed stripes : No Power settings : Disabled -------------------------------------------------------- Logical Device segment information -------------------------------------------------------- Segment 0 : Present (3815447MB, SATA, HDD, Connector:0, Device:0) Z1Z7W7TR Logical Device number 1 Logical Device name : VOLUME 2 Block Size of member drives : 512 Bytes RAID level : Simple_volume Unique Identifier : 8D2AC9AC Status of Logical Device : Optimal Size : 3814390 MB Parity space : Not Applicable Read-cache setting : Enabled Read-cache status : On Write-cache setting : Enabled Write-cache status : Off Partitioned : Yes Protected by Hot-Spare : Not Applicable Bootable : No Failed stripes : No Power settings : Disabled -------------------------------------------------------- Logical Device segment information -------------------------------------------------------- Segment 0 : Present (3815447MB, SATA, HDD, Connector:0, Device:1) W300M6DL ---------------------------------------------------------------------- Physical Device information ---------------------------------------------------------------------- Device #0 Device is a Hard drive State : Online Block Size : 512 Bytes Supported : Yes Transfer Speed : SATA 6.0 Gb/s Reported Channel,Device(T:L) : 0,0(0:0) Reported Location : Connector 0, Device 0 Vendor : ATA Model : ST4000NM0033-9ZM Firmware : SN04 Serial number : Z1Z7W7TR World-wide name : 5000C5007A858665 Reserved Size : 1072920 KB Used Size : 3814400 MB Unused Size : 64 KB Total Size : 3815447 MB Write Cache : Enabled (write-back) FRU : None S.M.A.R.T. : No S.M.A.R.T. warnings : 0 Power State : Full rpm Supported Power States : Full rpm,Powered off SSD : No Temperature : Not Supported NCQ status : Enabled ---------------------------------------------------------------- Device Phy Information ---------------------------------------------------------------- Phy #0 PHY Identifier : 0 SAS Address : 30000D1107221503 Attached PHY Identifier : 3 Attached SAS Address : 50000D1107221500 Device #1 Device is a Hard drive State : Online Block Size : 512 Bytes Supported : Yes Transfer Speed : SATA 6.0 Gb/s Reported Channel,Device(T:L) : 0,1(1:0) Reported Location : Connector 0, Device 1 Vendor : ATA Model : ST4000DM000-1F21 Firmware : CC52 Serial number : W300M6DL World-wide name : 5000C50069ECC48B Reserved Size : 1072920 KB Used Size : 3814400 MB Unused Size : 64 KB Total Size : 3815447 MB Write Cache : Enabled (write-back) FRU : None S.M.A.R.T. : No S.M.A.R.T. warnings : 0 Power State : Full rpm Supported Power States : Full rpm,Powered off,Reduced rpm SSD : No Temperature : Not Supported NCQ status : Enabled ---------------------------------------------------------------- Device Phy Information ---------------------------------------------------------------- Phy #0 PHY Identifier : 0 SAS Address : 30000D1107221500 Attached PHY Identifier : 0 Attached SAS Address : 50000D1107221500 ---------------------------------------------------------------------- Connector information ---------------------------------------------------------------------- Connector #0 Connector Name : CN0 ------------------------------------------------------------------- Lane Information ------------------------------------------------------------------- Lane #0 Channel ID : 0 Device ID : 0 SAS Address : 50000D1107221500 PHY Identifier : 3 ---------------------------------------------------------------- Lane SAS Phy Information ---------------------------------------------------------------- SAS Address : 50000D1107221500 Attached PHY Identifier : 0 Attached SAS Address : 30000D1107221503 Negotiated Logical Link Rate : PHY enabled - 6 Gbps Lane #1 Channel ID : 0 Device ID : 1 SAS Address : 50000D1107221500 PHY Identifier : 0 ---------------------------------------------------------------- Lane SAS Phy Information ---------------------------------------------------------------- SAS Address : 50000D1107221500 Attached PHY Identifier : 0 Attached SAS Address : 30000D1107221500 Negotiated Logical Link Rate : PHY enabled - 6 Gbps Command completed successfully.
Прошу подсказать команды — как заставить работать собственный кэш контроллера для записи, и как правильно выключить буферы дисков, как я понимаю одновременно два буфера использовать категорически неправильно.
Tert Advanced member Сообщения: 4233 Зарегистрирован: 19 янв 2003, 08:09 Откуда: Москва Контактная информация:
Как добиться максимальной скорости записи SSD на контроллере P420
При настройках по умолчанию скорость чтения SSD хорошая, но вот с записью явно что-то не то.
На этом скриншоте показана скорость 4 дисков SSD Samsung Evo 250GB в нулевом рейде

Побороть эту проблему можно если включить дисковый кеш, который драматически влияет на скорость записи.
Для того чтобы его включить нужно запустить одну из утилит HP для конфигурования рейдов, в данном случае HP smart storage administrator. Выбрать нужный контроллер из списка и нажать кнопку «Modify controller settings»

В открывшемся окне нужно установить птичку на опции «Physical Drive Write Cache State» -> Enabled

Для применения новых настроек нажать кнопку «Save settings».
После этого скорость записи на том же логическом диске будет значительно быстрее:
| Drive cache disabled | Drive cache enabled |
![]() |
![]() |
Тест проводился на сервере HP Proliant DL360 G7 с установленным контроллером HP Smart array P420 c 512MB кеша
(кеш не используется при работе с SSD но требуется для работы контроллера).
ВАЖНО! Дисковый кэш на пользовательских SSD энергозависим. Если у сервера отключится питания, то содержимое такого кэша пропадет. Поэтому перед включением кэша нужно убедиться, что сервер защищен от аварийных отключений света.